Btdin BTicino

Smart device for controlling devices with absorption up to 80A

BT-FC80AC | 8005543706022
Smart device for controlling and measuring the consumption of appliances with absorption <80A equipped with a dry contact. Range 12V/30Vdc or 230Vac 2A max. Ideal for managing and measuring heating appliances, wallboxes and electric vehicle charging stations, ventilation and irrigation systems and any other device equipped with a clean contact for control. Not usable for shutter automation. A toroid is supplied to measure the current absorbed by the max load. 80A. Management of functions via the Home + Control app and compatible with the FC80GCS load management module. Dimensions 1 DIN module. Power supply 100-240Vac 50/60 Hz.
Description

Btdin with Netatmo CONNECTED DRY CONTACT with maintained contacts 100 - 240V~ 50/60Hz with a single-phase closed 80A coil to remote-control loads via their dry contact input in off-peak/peak time or ON/OFF (real time or programmed) modes.

Product characteristics
  • Equipped with a dry contact input: 12V/30V DC or 230V ~ Imin 0,01A / Imax 2A​
  • Maintained contact. Normaly closed or normaly closed
  • Energy consumption: equipped with a single-phase up to 80A closed measurement coil to get energy data to whom the Connected Dry Contact is wired to.
  • Compatible with the load shedding scenario. Works with the Connected Load Shedder 412172
  • Keep constantly up-to-date with the consumption of your appliance and remotely remote-control it from your smartphone wherever you are within the Home + Control app.
Recommendations / Restrictions
  • Requires beforehand the installation of a "With Netatmo" gateway such as for example the Control module, the Power-outlet gateway, etc… When working on electricity for your safety turn-off the main protection device in the electrical panel-board.
Products benefits
Installation
  • Easy cabling part. All configuration steps are done within the smartphone app Home + Control
Usage
  • Scheduling: automatic opening and reclosing action scenarios based on a timeline. (daily/weekly/specific events such as “holidays”) or the Off-peak/peak time electrical contract
Advantages
  • Versatile offer: can fit anykind of loads with dry contact input terminal such as electrical vehicules charging stations, watering system, ventilation system, etc…
  • Voice assistant compatible
  • Part of the Legrand Connected Home environement. Works with Home+ Control smartphone app
Technical Characteristics
Supply voltage AC 50 Hz (Min-Max) 100-240 V
Supply voltage AC 60 Hz (Min-Max) 100-240 V
Voltage type (supply voltage) AC
Number of digital inputs 1
Number of digital outputs 1
Digital inputs configurable No
Digital outputs configurable No
Input current at signal 1 0.5 mA
Permitted voltage at input (Min-Max) 0-240 V
Type of voltage (input voltage) AC
Type of digital output Relay
Permitted voltage at output (Min-Max) 5-250 V
Type of output voltage AC/DC
Short-circuit protection, outputs available No
Number of HW-interfaces industrial Ethernet 0
Number of interfaces PROFINET 0
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 0
Number of HW-interfaces serial TTY 0
Number of HW-interfaces parallel 0
Number of HW-interfaces wireless 1
Number of HW-interfaces USB 0
Number of HW-interfaces other 0
With optical interface No
Supporting protocol for TCP/IP No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for ASI No
Supporting protocol for KNX No
Supporting protocol for Modbus No
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for LON No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFINET CBA No
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Radio standard Bluetooth No
Radio standard WLAN 802.11 No
Radio standard GPRS No
Radio standard GSM No
Mobile communications standard 3G (UMTS) No
IO link master No
System accessory No
Degree of protection (IP) IP3X
Type of electric connection Screw connection
Time delay at signal change (Min-Max) 200-300 ms
Fieldbus connection over separate bus coupler possible No
Suitable for rail mounting Yes
Wall mounting/direct mounting No
Front built-in possible No
Rack-assembly possible No
Suitable for safety functions No
SIL according to IEC 61508 None
Performance level according to EN ISO 13849-1 None
Appendant operation agent (Ex ia) No
Appendant operation agent (Ex ib) No
Explosion safety category for gas None
Explosion safety category for dust None
Width 17.8 mm
Height 95.9 mm
Depth 71 mm
Documentation
2 documents
Agreement
LGMVVEVWXT | FILE (162 KB) | EN · IT
PEP-EPD
LGRP-02216-V01.01-EN | PDF (944 KB) | EN
1 documents
Brochure
3246839 | PDF (8.1 MB) | EN