Accessories BTicino

BUS/SCS cable, unshielded, for underground installation in appropriate conduits. Coil length 200 m

BT-336904 | 8012199654362
Specific BUS/SCS cable, unshielded, consisting of a white external sheath and 2 x 0.50 mm2 brown and brown/white twisted flexible conductors. Insulation 400 V. In compliance with the standards: EN50575 EN60811, EN50289, EN50290, EN60228, EN50265-2-1, EN50395, EN50396 as described in the IMQ CPT 062 document. Cable suitable for underground installation inside appropriate conduits (for the details see the technical sheet). Coil length 200 m. Class of reaction to fire according to the CPR Regulation: Eca.
Description

Specific BUS/SCS cable, unshielded, consisting of a white external sheath and 2 x 0.50 mm2 brown and brown/white twisted flexible conductors. Insulation 400 V. Coil length 200 m.

Product characteristics
  • Specific BUS/SCS cable
  • Insulation 400 V.
  • In compliance with the standards: EN50575 EN60811, EN50289, EN50290, EN60228, EN50265-2-1, EN50395, EN50396
  • Length 200 m.
  • Class of reaction to fire according to the CPR Regulation: Eca.
Products benefits
Installation
  • Cable suitable for underground installation inside appropriate conduits.
Advantages
  • Specific BUS/SCS cable and for MyHome installations
Technical Characteristics
Conductor material Copper
Conductor surface Bare
Nominal cross section conductor 0.5 mm²
AWG size 20
Nominal cross section conductor (AWG) 20 kcmil
Diameter conductor 1.7 mm
Conductor category Class 2 = stranded
Number of cores 2
Twisted cores Yes
Material core insulation Other
Specification core insulation Other
Core identification Colour
Core colour White
With protective conductor No
Max. permitted conductor temperature 70 °C
Screen No
Drain wire No
Protective barrier None
Armouring/reinforcement None
Material outer sheath Polyvinyl chloride (PVC)
Specification material outer sheath Polyethylene (PE)
Colour outer sheath White
Low smoke according to EN IEC 61034-2 No
Reaction-to-fire according to EN 13501-6: Class Eca
Reaction-to-fire according to EN 13501-6: Smoke production None
Oil resistant according to EN IEC 60811-404 No
Low temperature resistant according to EN 60811-504+505+506 Yes
Outer diameter approximate 4.8 mm
Permitted cable outer temperature during assembling/handling (Min-Max) -15-70 °C
Permitted cable outer temperature after assembling without vibration (Min-Max) -15-70 °C
Nominal voltage U0 400 V
Nominal voltage U 400 V
Storage temperature (Min-Max) -15-70 °C
Documentation
1 documents
Technical Sheet
ST-00000253-EN | PDF (74 KB) | EN
1 documents
PEP-EPD
LGRP-00938-V01.01-EN | PDF (968 KB) | EN
6 documents
Brochure
BRO-LNOW-2M | PDF (15.9 MB) | EN
Brochure
BRO-LNOW-3M | PDF (16.3 MB) | EN
Catalog Commercial Page
CAT-LNOW-2M | PDF (23.1 MB) | EN
Catalog Commercial Page
CAT-LNOW-3M | PDF (22.5 MB) | EN
DOP
LGESKTEMZN | FILE (235 KB) | EN · IT
DOP
LGTJFENQCU | FILE (276 KB) | EN · IT