KNX Legrand

Multi-application controller with KNX

LG-048422 | 3245060484224
Multi-application controller with KNX16 inputs and 16 outputs can realize multiple functions including:- Control ON-OFF Lights or dimming via DALI protocol- Control of shutters- Control controllable outlets- Measurement of consumption of the connected loads (only on certain outputs)Each output can be controlled by traditional electromechanical devices orKNX devices and can be configured to operate according to three operating profilesdifferent.Connection to the bus via red-Black KNX connector.Supply voltage 27-50 VdcDIN rail mounting. Dimensions: 12 DIN modules.
Description
Product characteristics
  • Power modules equipped with output contacts for controlling:different types of ON/OFF load (lighting, roller shutters, contactors, motors, etc.)a DALI dimming output for 64 ballasts max.
  • Loads are managed by the controls to which they are linked: either by BUS/KNX controls, or by wired connection input terminals (switches, push-buttons, volt-free contacts)
Technical Characteristics
Bus system KNX Yes
Bus system KNX-RF (Radio Frequency) No
Bus system radio frequency No
Bus system LON No
Bus system Powernet No
Other bus systems None
Mounting method DRA (DIN-rail adaptor)
Width in number of modular spacings 12
Local operation/hand operation Yes
With LED indication Yes
Number of digital inputs 16
Rated operating voltage (Min-Max) 27-56 V
Power consumption 1 W
With bus connection Yes
Min. depth of built-in installation box 66 mm
Degree of protection (IP) IP20
Width 213 mm
Height 83 mm
Depth 66 mm
degree of impact strength (IK) IK07
Operating / setting temperature (Min-Max) -5-45 °C
Storage temperature (Min-Max) -25-70 °C
Voltage type AC/DC
Terminal marking indication Yes
Halogen free Yes
Connection type Screwed terminal
Terminals capacity (Min-Max) 0.5-1.5 mm²
Connection type Cable
Label space/information surface Yes
Fitted with USB plug Yes
Connected object No
Documentation
2 documents
Technical Sheet
FT_S000074637EN_6 | PDF (3.1 MB) | EN
Instruction Use
LE05989AE | PDF (1.4 MB)
1 documents
Agreement
LGJROABTOV | FILE (181 KB) | EN
2 documents
Brochure
BRO-KNX | PDF (7 MB) | EN
Catalog Commercial Page
CAT-KNX | PDF (6.1 MB) | EN
15 documents
Firmware
FW_LG-002638_2 | ZIP (8.1 MB)
Firmware
FW_LG-048422 | ZIP (206 KB)
Use case Firmware
USE_CASE_002697_2T_3PTS_1 | ZIP (1.9 MB) | EN
Use case Firmware
USE_CASE_002697_2T_PWM_2PTS_ON_OFF_1 | ZIP (2.6 MB) | EN
Use case Firmware
USE_CASE_002697_2T_PWM_3PTS_ON_OFF_1 | ZIP (3 MB) | EN
Use case Firmware
USE_CASE_002697_4T_3PTS_1 | ZIP (1.8 MB) | EN
Use case Firmware
USE_CASE_002697_4T_PWM_2PTS_ON_OFF_1 | ZIP (2.5 MB) | EN
Use case Firmware
USE_CASE_002697_4T_PWM_3PTS_ON_OFF_1 | ZIP (2.8 MB) | EN
Use case Firmware
USE_CASE_049041_2T_0_10V_1 | ZIP (2.2 MB) | EN
Use case Firmware
USE_CASE_049041_2T_ON_OFF_1 | ZIP (3 MB) | EN
Use case Firmware
USE_CASE_049041_2T_PWM_1 | ZIP (3 MB) | EN
Use case Firmware
USE_CASE_049041_4T_0_10V_1 | ZIP (2.1 MB) | EN
Use case Firmware
USE_CASE_049041_4T_0_10V_ON_OFF_1 | ZIP (3.2 MB) | EN
Use case Firmware
USE_CASE_049041_4T_ON_OFF_1 | ZIP (2.9 MB) | EN
Use case Firmware
USE_CASE_049041_4T_PWM_1 | ZIP (3 MB) | EN