Conto IME

Energy meter Conto D4-Pt MID

IM-CE4TBDTMID | 8032826514418
Conto D4-Pt MID - Energy meter, active MID (cl.B) and reactive (cl.2) Connection: via CT (5A) - Network: three-phase 4-wires unbalanced - Dimension: 4 DIN modules - Output: RS485 - Input (from CT) : 1A-5A - Voltage: 3x230/400V - Aux: self-supplied
Description

Electrical counter of active and reactive energy consumed by a three-phase circuit downstream the distribution protection. This device measures through current transformers all the electrical values of the circuit in a distribution board.

Product characteristics
  • Connection with CT up to 5A.
  • Communication: Modbus RS 485.
  • Double tariff or Pulse input to collect other meter (gas, water, electrical meters).
  • MID Certified.
  • Bidirectional measure of production and consumption energies.
Products benefits
Installation
  • Easy connection of communication thanks to removable connectors. One input connector for double tariff or Pulse input to collect water or gas meters without using added concentrator device.
Usage
  • Backlit display and simple access to easy reading of data. Pre-visualization of parameters. Settings mode protected by user code Bidirectional measure of production and consumption energies
Advantages
  • Measure of run hours on each tariff.
  • Phaseshift measure locally displayed.
Technical Characteristics
Type of meter Electronic
Nominal current (In) 5 A
Max. current (Imax) 63 A
Nominal voltage (Un) N-L (Min-Max) 90-265 V
Nominal voltage (Un) L-L (Min-Max) 156-460 V
Frequency (Min-Max) 49-61 Hz
Accuracy class B
Pole type Three conductor/four conductor
Model Direct measurement
Energy type Effective power and reactive power
Suitable for Purchase/supply
Tariff type Two-tariff
Tariff control External
Measurement type load profile No
Escapement mechanism Yes
Calibrated Yes
Approval Measuring Instruments Directive
Pulse output None
Type of indication Digital
Mounting method DRA (DIN-rail adaptor)
Width in number of modular spacings 4
Width 71.2 mm
Depth 66 mm
Height 92.4 mm
Type of interface RS-485
With lock code Yes
Number of positions total (counter) 9
Degree of protection (IP) IP54
Operating / setting temperature (Min-Max) -25-55 °C
Storage temperature (Min-Max) -25-70 °C
Voltage type AC
Terminal marking indication Yes
Colour Grey
RAL-number 7035
Halogen free Yes
Prewired No
Connection type Screwed terminal
Terminals capacity (Min-Max) 1-16 mm²
Label space/information surface No
Connected object No
Documentation
4 documents
Technical Sheet
IDP000192EN_06 | PDF (4.3 MB) | EN
Technical Sheet
IDP000192FR | PDF (2.4 MB) | EN · FR
Instruction Use
LE11303FR | PDF (3.2 MB) | EN · FR
Technical Guide
USER MANUAL IDM CONF IME EN | ZIP (4 MB) | EN
1 documents
PEP-EPD
LGRP-01746-V01.01-EN | PDF (908 KB) | EN
2 documents
Catalog Commercial Page
3226373 | PDF (16.9 MB) | EN
Trade Guide
PR_CE4TBDTMIDFR | PDF (321 KB) | EN · FR
1 documents
Software
IME_IDM_CONFIGURATOR_SETUP_2.02.00 1 | EXE (14.1 MB) | FR · EN · IT