Conto D2 MID - Energy meter, active multifunction (cl.B) Connection: direct - Network: single-phase - Dimension: 2 DIN modules - Output: MODBUS - Current: 63A - Aux: self-supplied
Description

Electrical counter of active and reactive energy consumed by a three-phase circuit downstream the distribution protection. This device measures through current transformers all the electrical values of the circuit in a distribution board.

Product characteristics
  • Connection with CT up to 5A.
  • Communication: MBus output.
  • Double tariff or Pulse input to collect other meter (gas, water, electrical meters).
  • MID Certified.
  • Bidirectional measure of production and consumption energies.
Products benefits
Installation
  • Easy connection of communication thanks to removable connectors. One input connector for double tariff or Pulse input to collect water or gas meters without using added concentrator device.
Usage
  • Backlit display and simple access to easy reading of data. Pre-visualization of parameters. Settings mode protected by user code Bidirectional measure of production and consumption energies
Advantages
  • Measure of run hours on each tariff.
Technical Characteristics
Type of meter Electronic
Nominal current (In) 10 A
Max. current (Imax) 63 A
Nominal voltage (Un) N-L (Min-Max) 197-265 V
Frequency (Min-Max) 49-61 Hz
Accuracy class B
Pole type Single phase
Model Direct measurement
Energy type Effective power and reactive power
Suitable for Purchase/supply
Tariff type Two-tariff
Tariff control External
Measurement type load profile No
Escapement mechanism Yes
Calibrated Yes
Approval Measuring Instruments Directive
Pulse output None
Type of indication Digital
Mounting method DRA (DIN-rail adaptor)
Width in number of modular spacings 2
Width 35.8 mm
Depth 66 mm
Height 92.4 mm
Type of interface M-bus (wired)
With lock code Yes
Number of positions total (counter) 9
Degree of protection (IP) IP54
degree of impact strength (IK) IK08
Operating / setting temperature (Min-Max) -25-55 °C
Storage temperature (Min-Max) -25-70 °C
Voltage type AC
Terminal marking indication Yes
Colour Grey
RAL-number 7035
Halogen free Yes
Prewired No
Connection type Screwed terminal
Terminals capacity (Min-Max) 1-16 mm²
Label space/information surface No
Connected object No
Documentation
6 documents
Technical Sheet
IDP000193_06 | PDF (4 MB) | EN · IT
Technical Sheet
IDP000193EN_06 | PDF (5.6 MB) | EN
Technical Sheet
IDP000193FR | PDF (864 KB) | EN · FR
Technical Sheet
IDP000377_IM-CE2DF3MTMID | PDF (248 KB) | EN
Instruction Use
LE11305FR | PDF (2.8 MB) | EN · FR
Instruction Use
LE11306FR | PDF (3 MB) | EN · FR
2 documents
Trade Guide
IDP000377FR | PDF (194 KB) | EN · FR
Catalog Commercial Page
3226373 | PDF (16.9 MB) | EN
1 documents
Software
IME_IDM_CONFIGURATOR_SETUP_2.02.00 1 | EXE (14.1 MB) | FR · EN · IT