MyHome BTicino

Basic probe flush-mounted version; it reads the ambient temperature in the range 0 – 40 °C.

BT-3454 | 8005543628782
Basic probe flush-mounted version, to be mounted in electrical junction boxes; it doesn’t have any internal temperature sensor, but it reads the ambient temperature information in the range 0 – 40 °C from an external wired sensor art. 3457, which must be mounted in the wall at a height of 1.5m from the floor level, exposed to air.
Description

Basic probe flush-mounted version, to be mounted in electrical junction boxes; it doesn’t have any internal temperature sensor, but it reads the ambient temperature information in the range 0 – 40 °C from an external wired sensor art. 3457.

Product characteristics
  • 2 modules
  • This device has 3 input terminals:- SCS: it is used for connection to the SCS bus.- PROBE: it is used for connection to the external temperature sensor.- REMOTE: it is used for connection to a remote contact, useful for different applications(e.g. to change the operating mode when a window is opened, to change theoperating function...).
  • To be associated to thetemperature sensor item 3457 and Vantageprobe item 8051
  • The associated 3457 must be mounted in the wall at a height of 1.5m from the floor level, exposed to air.
  • Noother sensors (except 3457 and 8051) can be connected to this probe, because the correct temperature readingcan’t be guaranteed.
Products benefits
Installation
  • The probe has one mechanical pushbutton, which is used only during deviceconfiguration.
Usage
  • The probe has 2 LEDs, one red and one green, used to point out information aboutdevice correct configuration and installation, as well as thermoregulation zone state.
Technical Characteristics
Model Clamp
Material Plastic
Length probe 2000 mm
Connection cable length 2 m
Width 50 mm
Height 50 mm
Depth 20 mm
degree of impact strength (IK) Not applicable
Degree of protection (IP) IP54
Operating / setting temperature (Min-Max) 0-40 °C
Storage temperature (Min-Max) -10-70 °C
Nominal voltage (Min-Max) 18-27 V
Supply current (Min-Max) 0.001-0.010 A
Halogen free Yes
Cable nature for connection Flexible
Mounting method DIN rail
Connected object No
Operating method SCS
Documentation
3 documents
Instruction Use
LE11056AA | PDF (715 KB)
Installation Guide
GUI-MHOME | PDF (22.7 MB) | EN
Technical Sheet
ST-00000301-EN | PDF (179 KB) | EN
5 documents
Brochure
BRO-LNOW-2M | PDF (15.9 MB) | EN
Brochure
BRO-LNOW-3M | PDF (16.3 MB) | EN
Brochure
BRO-MHOME | PDF (2.7 MB) | EN
Catalog Commercial Page
CAT-LNOW-2M | PDF (23.1 MB) | EN
Catalog Commercial Page
CAT-LNOW-3M | PDF (22.5 MB) | EN